Images are for guidance only and might not represent the final product.

Tungsten-Rhenium Spooled Wire (W74-Re26)

Available Configurations

Properties common to all products in this list

Commodity: Alloys Material: Tungsten/Rhenium Form: Wire Composition: W 74/Re 26 Temper: Annealed Thermocouple Compatibility: Type C (-)
Diameter Length Other Variants
0.125 – 0.5 mm 0.1 – 100 m W70-Re30
W75-Re25
W95-Re5
W97-Re3

Need custom configurations? Please contact us.

Tungsten-Rhenium Spooled Wire (W74/Re26) is the negative thermoelectric leg of the Type C thermocouple pair (W95Re5 positive, W74Re26 negative), the thermocouple type with the highest temperature capability of any standard type, confirmed for use up to approximately 2000°C in metallurgy, power generation, and aerospace under protective, inert, or vacuum atmospheres. Service is restricted to non-oxidizing conditions: both tungsten-rhenium alloys oxidize rapidly in air above approximately 500°C, and oxidation-resistant coatings are required where brief atmospheric exposure is unavoidable. The 26% rhenium content improves ductility and workability of the tungsten matrix relative to pure tungsten, which is critical for drawing to thermocouple wire gauges, and defines the negative thermoelectric character of this leg relative to the lower-rhenium positive leg. Significant EMF drift develops above approximately 1200°C, and in situ calibration using fixed-point miniature cells is confirmed in the literature as a technique to monitor and compensate drift in applications such as nuclear reactor instrumentation where removal for recalibration is not possible. In industry, this wire is used for Type C thermocouple assembly in vacuum furnaces, refractory metal sintering systems, and nuclear and aerospace propulsion test rigs. In research, it is used for Type C calibration at high-temperature fixed points, stability and drift investigations, and thin-film W-Re thermocouple fabrication for aerospace surface temperature sensing.
Starting at $320.00 each
No Minimum order Approx. 2 weeks leadtime Free technical support Free delivery from $750

Certified Thermocouple Pairs

For applications where the pairing itself needs to be verified, not just each leg individually, certified thermocouple pairs are available through our premium manufacturing network with decades of dedicated production experience and in-house, accredited calibration laboratory.

Thermocouple wire drawing process
Capability Details
Thermocouple types available S, R, B only (platinum and platinum-rhodium alloys)
Pair matching Precision-matched from the same calibrated production batch
Manufacturing standards Platinum refined in-house to 99.995% purity; Rhodium to 99.98%. Wire diameters from 0.04mm to 1.6mm. Every batch pre-annealed and calibrated before shipping.
Testing & calibration Fixed-point method (zinc, aluminium, gold, palladium reference points). EMF evaluated against EN 60584-1 and ASTM E230/E230M tolerance classes. ISO/IEC 17025-accredited laboratory.
Certification Supplied with calibration certificate. ISO 9001 & ISO 14001 certified manufacturing.
Typical use Calibration, high-accuracy, or traceability-critical applications
To discuss a custom certified thermocouple pair, please submit a quote request or contact us.

Want to learn more? Explore our complete thermocouple range, covering both our standard and custom offerings.

Key Features

Tungsten-Rhenium Spooled Wire (W74/Re26) is the negative thermoelectric leg of the Type C thermocouple pair (W95Re5 positive, W74Re26 negative), the thermocouple type with the highest temperature capability of any standard type, confirmed for use up to approximately 2000°C under protective, inert, or vacuum atmospheres:

Highest temperature capability of any standard thermocouple type

Type C is confirmed for temperature measurement up to approximately 2000°C in protective, inert, or vacuum atmospheres, higher than any platinum-based thermocouple type. W74/Re26 provides the negative leg in this pairing, with a composition giving it its negative thermoelectric character relative to the lower-rhenium W95/Re5 positive leg.

Restriction to non-oxidizing atmospheres

Both tungsten-rhenium alloys oxidize rapidly in air above approximately 500°C. Service is restricted to protective, inert, or vacuum atmospheres; oxidation-resistant coatings are required where brief atmospheric exposure is unavoidable. This restriction defines the primary application constraint.

Improved ductility from 26% rhenium content

The 26% rhenium content improves ductility and workability of the tungsten matrix relative to pure tungsten, which is critical for drawing to thermocouple wire gauges. The rhenium content also defines the negative thermoelectric character of this leg relative to the W95/Re5 positive leg.

EMF drift at high temperatures and in situ calibration

Significant EMF drift develops above approximately 1200°C. In situ calibration using fixed-point miniature cells is confirmed as a technique to monitor and compensate drift in applications such as nuclear reactor instrumentation where removal for recalibration is not possible.

Thin-film W-Re thermocouple applications

Beyond wire thermocouple use, W74/Re26 alloy is used in thin-film W-Re thermocouple fabrication for aerospace surface temperature sensing where conventional wire thermocouple installation is impractical.

Industrial Applications

Tungsten-Rhenium Spooled Wire (W74/Re26) is used as the Type C negative leg in ultra-high temperature measurement under protective atmospheres, and in thin-film thermocouple research:

✦ Type C thermocouple assembly in vacuum furnaces and sintering systems
Used as the negative leg in Type C thermocouple assemblies for temperature measurement in vacuum furnaces and refractory metal sintering systems operating above the capability of platinum-based thermocouple types, where protective or vacuum atmosphere service excludes oxidation.
✦ Nuclear reactor instrumentation
Applied in Type C thermocouple assemblies for nuclear reactor core temperature measurement where the high-temperature capability, atmosphere compatibility, and radiation tolerance of W-Re thermocouples are required, and where in situ calibration techniques are used to compensate EMF drift.
✦ Aerospace propulsion test rigs
Used in Type C thermocouple assemblies in aerospace propulsion test facilities operating at temperatures above the range of platinum-based types, under inert or protective atmosphere test conditions.
✦ Type C calibration and thermoelectric stability research
Used in research for Type C calibration at high-temperature fixed points, stability and drift investigations, and thin-film W-Re thermocouple fabrication for aerospace surface temperature sensing.

Frequently Asked Questions

Answers to the questions we are asked most often about Tungsten-Rhenium Alloy Spooled Wire (W74/Re26), covering its role as the Type C thermocouple − leg, atmosphere requirements, temperature limits, and applications in extreme high-temperature environments:

What is W74/Re26 alloy wire and what thermocouple type uses it?

Tungsten-rhenium alloy (W74/Re26) wire is the − leg of the Type C thermocouple, which operates at up to 2,000 °C (vacuum/inert/protective atmosphere only). Tungsten-rhenium alloys are specified for thermocouple applications above the useful range of all platinum-based types (approximately 1,600 °C), covering vacuum furnaces, sintering systems, and metallurgical processes that require temperature measurement up to and beyond 2,000 °C. The rhenium addition to tungsten significantly improves ductility and wire-drawing characteriztics compared with pure tungsten, which is too brittle to draw reliably to fine thermocouple gauges.

What atmosphere is W74/Re26 wire compatible with, and why does this matter?

Tungsten-rhenium alloys oxidize rapidly above approximately 500 °C in open air. W74/Re26 wire — and all tungsten-rhenium thermocouple wire — must be used in vacuum, inert (argon, helium), or protective atmosphere environments only. Exposure to oxygen at elevated temperatures causes irreversible oxidation that destroys the thermocouple within minutes. This atmosphere restriction is the defining operational constraint of Type C thermocouples and must be observed throughout the service life of the thermocouple element, including during installation and any maintenance operations.

What are the primary applications for Type C thermocouples using W74/Re26 wire?

Type C is specified wherever temperature measurement above the platinum-rhodium limit (approximately 1,600 °C) is required under protective atmosphere. Primary applications include vacuum furnaces for sintering, annealing, and brazing of refractory metals and ceramics; arc melting and casting of refractory alloys; nuclear reactor fuel and cladding development; plasma physics research; aerospace propulsion testing; and high-temperature materials characterization. These are all environments where the vacuum or protective atmosphere requirement is already present for process reasons, making the atmosphere constraint of tungsten-rhenium thermocouples a natural fit rather than an additional burden.

How does Type C (W74/Re26 positive) compare to Type D in the Goodfellow range?

Both Type C and Type D are tungsten-rhenium thermocouple types for extreme high-temperature vacuum or protective-atmosphere service. Type C uses W95/Re5 (positive) and W74/Re26 (negative), covering up to 2,000 °C. Type D uses W97/Re3 (positive) and W75/Re25 (negative), covering up to 2,315 °C — the highest temperature ceiling of any standard thermocouple type. Type D also offers slightly improved ductility in the negative leg (W75/Re25 vs W74/Re26) due to the different rhenium distribution. For most vacuum furnace applications below 2,000 °C, Type C is the established standard; Type D is specified where the additional temperature headroom of 315 °C is required.

Why is rhenium added to tungsten for thermocouple wire?

Pure tungsten is extremely brittle in wire form, making it difficult to draw to fine gauges and prone to fracture during handling and installation. The addition of rhenium — through the 'rhenium ductilising effect' — significantly improves the room-temperature ductility of tungsten, allowing it to be drawn to thermocouple-grade diameters and handled without fracture. The specific rhenium percentages used in Type C and D thermocouples (W74/Re26 and W95/Re5 (Type C positive leg)) are optimized to balance ductility, thermoelectric sensitivity, and reproducibility of the EMF-temperature relationship.

What are the practical handling precautions for W74/Re26 wire?

Tungsten-rhenium wire is significantly more brittle than nickel-based or platinum-based thermocouple wire and must be handled carefully to avoid kinking, bending to tight radii, or mechanical shock that would cause fracture. The wire should be wound onto sufficiently large diameter formers and should not be bent to radii below the minimum specified for the gauge. During installation in furnace systems, the thermocouple should be supported along its length to prevent vibration-induced fatigue at high temperatures. The atmosphere must be established before the wire is heated above 500 °C.

What nuclear and materials science applications use W74/Re26 wire?

Tungsten-rhenium thermocouple wire is used in nuclear reactor instrumentation where measurement of fuel, cladding, and coolant temperatures in high-flux environments under protective atmosphere is required. Its radiation hardness and high-temperature capability make it suitable for in-pile measurements in fission reactor development and fusion reactor diagnostics. In materials science, it is used for temperature measurement during high-temperature testing of refractory metals, ultra-high-temperature ceramics, and nuclear fuel materials where the protective atmosphere required for the specimen is also suitable for the thermocouple.

What diameter and length options are available for W74/Re26 wire?

Tungsten-rhenium alloy (W74/Re26) spooled wire is available in a range of diameters and lengths suited to thermocouple fabrication. Diameter tolerance is ±10% and length tolerance is +5% / −1%. For custom configurations, please contact us.

Synonyms

W-Re Reeled Wire W74Re26 Spooled Wire Wolfram-Rhenium Reeled Wire Tungsten-Rhenium Reeled Wire Wolfram-Rhenium Spooled Wire
each

Choose Your Options

Close

Available Configurations

Properties common to all products in this list

Commodity: Alloys Material: Tungsten/Rhenium Form: Wire Composition: W 74/Re 26 Temper: Annealed Thermocouple Compatibility: Type C (-)

We are collecting your products, please wait!...

Shipping restrictions and charges may apply for some hazardous materials.

Tolerances

Wire
Diameter ±10%
Length +5% / -1%