Images are for guidance only and might not represent the final product.

Polyimide-Insulated Copper Wire

Available Configurations

Properties common to all products in this list

Composition: Cu Form: Insulated Wire Material: Copper CAS Number: 7440-50-8 Commodity: Metals Insulation: Polyimide
Conductor Diameter Length Insulation Thickness Temper ⓘ Thermocouple Compatibility Other Variants
0.025 – 0.5 mm 0.1 – 10000 m 0.002 – 0.06 mm Annealed
As Drawn
Type T (+) Polyesterimide-Insulated
OFHC
Polyurethane-Insulated
PTFE-Insulated

Need custom configurations? Please contact us.

Polyimide-Insulated Copper Wire (Cu, 99.99%) is a high-conductivity copper wire with polyimide film insulation, combining near-maximum bulk copper electrical conductivity with a service ceiling of 315°C continuous and 400°C short-term. Polyimide is confirmed across the aerospace and electrical engineering literature as the insulation standard for aviation motor and generator windings and precision transformer windings, where it retains dielectric integrity, chemical resistance, and dimensional stability at temperatures that degrade polyester and polyurethane coatings. The tradeoff is that polyimide is harder to strip for termination than softer organic insulations, owing to its heat and solvent resistance. Beyond these winding applications, this wire serves as the positive thermoelectric leg of the Type T thermocouple pair when paired with Constantan (Cu-Ni); Type T covers approximately -200°C to 350°C and is well suited to cryogenic and low-to-mid-range temperature measurement. In industry, it is used for aerospace motor and generator winding wire, transformer and inductor winding, precision electromagnetic coil fabrication, and Type T thermocouple probe and lead assembly. In research, it is used for insulation thermal aging and dielectric performance studies, high-temperature winding reliability investigations, and Type T thermocouple calibration and EMF stability characterization.
Starting at $188.00 each
No Minimum order Free technical support Free delivery from $750

Certified Thermocouple Pairs

For applications where the pairing itself needs to be verified, not just each leg individually, certified thermocouple pairs are available through our premium manufacturing network with decades of dedicated production experience and in-house, accredited calibration laboratory.

Thermocouple wire drawing process
Capability Details
Thermocouple types available S, R, B only (platinum and platinum-rhodium alloys)
Pair matching Precision-matched from the same calibrated production batch
Manufacturing standards Platinum refined in-house to 99.995% purity; Rhodium to 99.98%. Wire diameters from 0.04mm to 1.6mm. Every batch pre-annealed and calibrated before shipping.
Testing & calibration Fixed-point method (zinc, aluminium, gold, palladium reference points). EMF evaluated against EN 60584-1 and ASTM E230/E230M tolerance classes. ISO/IEC 17025-accredited laboratory.
Certification Supplied with calibration certificate. ISO 9001 & ISO 14001 certified manufacturing.
Typical use Calibration, high-accuracy, or traceability-critical applications
To discuss a custom certified thermocouple pair, please submit a quote request or contact us.

Want to learn more? Explore our complete thermocouple range, covering both our standard and custom offerings.

Key Features

Polyimide-Insulated Copper Wire is a high-conductivity copper wire with polyimide film insulation, combining near-maximum bulk copper electrical conductivity with a service ceiling of 315°C.

Near-maximum copper conductivity with high-temperature insulation

99.99% purity copper delivers near-maximum bulk electrical conductivity, minimizing resistive losses in winding and lead applications. The polyimide film insulation raises the service ceiling to 315°C in continuous service and 400°C short-term, well above the limits of polyester or polyurethane alternatives, enabling these conductivity levels to be used in high-temperature winding environments where other organic insulations would degrade.

Polyimide is the aviation winding insulation standard

Polyimide is confirmed across the aerospace and electrical engineering literature as the insulation standard for aviation motor and generator windings and precision transformer windings. It retains dielectric integrity, chemical resistance, and dimensional stability at temperatures that degrade polyester and polyurethane coatings, qualifying it for winding applications in aircraft electrical systems where thermal margins are tight and insulation failure is not acceptable.

Chemical resistance and dimensional stability at elevated temperatures

The polyimide coating maintains its geometry and dielectric performance under combined thermal and chemical exposure, resisting the solvents, lubricants, and hydraulic fluids present in aerospace and industrial motor environments where softer organic insulations would swell, crack, or lose dielectric integrity.

Type T thermocouple positive leg

High-purity copper wire is the positive thermoelectric leg of the Type T thermocouple pair when combined with Constantan (Cu-Ni). Type T covers approximately -200°C to 350°C and is well suited to cryogenic and low-to-mid-range temperature measurement, with the polyimide insulation providing dielectric isolation across the operating range.

Harder to strip than softer organic insulations

Polyimide’s heat and solvent resistance, which gives it its thermal performance advantage, also makes it harder to strip for termination than polyester or polyurethane coatings. Mechanical or laser stripping is typically used rather than chemical or soldering-through methods. This is the principal handling trade-off relative to more easily terminated insulation systems.

Industrial Applications

Polyimide-Insulated Copper Wire is used for high-temperature winding applications in aerospace and precision electrical equipment, and as the positive leg in Type T thermocouple assemblies:

✦ Aerospace motor and generator winding
Used as winding wire in aerospace motor and generator assemblies where the combination of high copper conductivity, polyimide insulation integrity at elevated operating temperatures, and resistance to aviation fluids qualifies it as the standard winding wire for airborne electrical machines.
✦ Transformer and inductor winding
Applied as winding wire in precision transformers and inductors operating at elevated temperatures, where polyimide insulation maintains dielectric isolation and dimensional stability at winding temperatures that exceed the service limits of polyester or polyurethane film insulations.
✦ Precision electromagnetic coil fabrication
Used for precision electromagnetic coil fabrication in industrial and scientific instrumentation where high conductivity, tight dimensional tolerances on the insulated wire diameter, and insulation stability over the coil service life are simultaneously required.
✦ Type T thermocouple probe and lead assembly
Applied as the positive leg in Type T thermocouple probe and lead assemblies for temperature measurement from cryogenic conditions to approximately 350°C, where the polyimide insulation provides dielectric isolation across the full operating range and the 99.99% copper purity ensures a well-characterized thermoelectric output.
✦ Insulation thermal aging, dielectric performance, and winding reliability studies in research
Used in research for insulation thermal aging and dielectric performance studies, high-temperature winding reliability investigations, and Type T thermocouple calibration and EMF stability characterization, where the well-defined copper purity and polyimide insulation system provide a reproducible reference conductor.

Frequently Asked Questions

Answers to the questions we are asked most often about Polyimide-Insulated Copper Wire, covering the polyimide insulation's thermal advantage over alternatives, the Type T thermocouple role, stripping trade-offs, purity grade, and available configurations:

What is Polyimide-Insulated Copper Wire and what makes it different from other insulated copper wire?

Polyimide-Insulated Copper Wire is 99.99% purity copper wire with a polyimide film coating applied to the conductor surface. The purity grade delivers near-maximum bulk copper electrical conductivity — resistivity of 1.69 µΩ·cm at 20°C — while the polyimide insulation raises the continuous service ceiling to 315°C and the short-term limit to 400°C. Most insulated copper wire uses polyester or polyurethane coatings, which begin to degrade below 200°C. Polyimide is the correct choice wherever the winding or lead wire operates at temperatures those softer organic insulations cannot sustain.

Why is polyimide the standard insulation for aerospace motor and generator windings?

Polyimide retains its dielectric integrity, chemical resistance, and dimensional stability at temperatures that degrade polyester and polyurethane coatings. In aerospace motor and generator windings, thermal margins are tight, operating temperatures are elevated, and the insulation is continuously exposed to aviation fluids — lubricants, hydraulic fluid, and fuel vapour — that would cause softer organic coatings to swell, crack, or lose dielectric integrity. Polyimide is resistant to all of these. Its status as the insulation standard for airborne electrical machines follows directly from these properties.

What is the continuous service temperature of the polyimide insulation, and what are the limits of alternatives?

The polyimide coating on this wire is rated to 315°C continuous service and 400°C short-term. Polyurethane insulation — which is directly solderable and highly flexible — is typically rated to around 105°C continuous. Standard polyester insulation is rated to approximately 155°C continuous. Polyimide therefore extends the usable service temperature by roughly 160°C above polyester and 210°C above polyurethane, at the cost of easier strippability that those alternatives offer.

What is the Type T thermocouple role of this wire?

High-purity copper wire is the positive thermoelectric leg (+) of the Type T thermocouple pair (Copper vs. Constantan), covering approximately −200°C to 350°C. The polyimide insulation provides dielectric isolation between the copper positive leg and the Constantan negative leg across the full operating range, including at sub-zero and cryogenic temperatures where polyimide remains stable. Type T is the standard choice for cryogenic and low-to-mid-range temperature measurement because of the stable and well-characterized thermoelectric output of copper and Constantan at sub-ambient temperatures.

What is the trade-off with polyimide insulation compared to polyester or polyurethane?

Polyimide's heat and solvent resistance — the properties that give it its thermal performance advantage — also make it harder to strip for termination than polyester or polyurethane coatings. Polyurethane insulation dissolves in molten solder at standard soldering temperatures, allowing the wire to be soldered directly without stripping. Polyester can be burned back or abraded. Polyimide requires mechanical stripping (abrasive wheels, precision blade strippers) or laser ablation to remove cleanly without damaging the conductor. This is the principal handling trade-off to account for when designing termination processes.

How does the 99.99% copper purity affect electrical performance?

At 99.99% purity, residual impurities that would scatter conduction electrons are minimized, producing a resistivity of 1.69 µΩ·cm at 20°C — close to the theoretical maximum conductivity for copper. In winding applications, this directly reduces I²R resistive losses across the full winding length, contributing to motor and transformer efficiency. In thermocouple applications, the well-defined purity ensures a consistent and reproducible thermoelectric output, which is the basis for accurate Type T temperature measurement and EMF calibration work.

What winding applications is this wire suited to beyond aerospace?

Beyond aerospace motor and generator windings, Polyimide-Insulated Copper Wire is used in precision transformers and inductors operating at elevated temperatures where polyimide maintains dielectric isolation at winding temperatures that exceed the service limits of polyester or polyurethane; in precision electromagnetic coil fabrication for industrial and scientific instrumentation where high conductivity, tight dimensional tolerances on the insulated wire diameter, and insulation stability over the coil service life are simultaneously required; and in any winding application where thermal cycling between ambient and elevated temperatures would degrade softer organic insulations over the service life of the assembly.

What research applications use Polyimide-Insulated Copper Wire?

Research applications include insulation thermal ageing and dielectric performance studies, where the well-defined polyimide insulation system and known copper purity provide a reproducible reference conductor; high-temperature winding reliability investigations, where samples are cycled through thermal profiles representative of aerospace or industrial service; and Type T thermocouple calibration and EMF stability characterization, where the 99.99% copper purity ensures that measured deviations from the standard EMF table reflect experimental conditions rather than conductor impurity effects.

What are the available conductor diameters, insulation thicknesses, and lengths?

Polyimide-Insulated Copper Wire is available with conductor diameters from 0.025 mm to 0.5 mm and insulation thicknesses from 0.002 mm to 0.06 mm, in lengths from 0.1 m to 1,000 m. Conductor diameter tolerance is ±10%; insulation thickness is nominal; length tolerance is +5% / −1%. For conductor diameters, insulation thicknesses, or lengths outside this range, please contact us.

When should I choose Polyimide-Insulated Copper Wire over polyurethane- or polyester-insulated copper wire?

Choose Polyimide-Insulated Copper Wire when the winding or lead wire will operate above 155°C — the upper limit of polyester — or when the assembly environment involves aviation fluids, aggressive solvents, or high-temperature chemical exposure that would degrade softer organic coatings. Choose polyurethane-insulated copper wire when direct solderability is the priority and the operating temperature does not exceed approximately 105°C — for example in portable thermocouple probes, embedded sensors, and board-level assemblies where stripping is impractical. Choose polyester-insulated copper wire for moderate-temperature general winding where lower cost is a priority and the temperature limit of 155°C is acceptable.

Synonyms

PI Cu Coated Wire Enamelled Copper Wire Polyimide Magnet Wire Polyimide Copper Jacketed Wire Polyimide Copper Coated Wire

Material Properties

Atomic Properties
Element Value
Atomic number 29
Crystal structure Face centred cubic
Electronic structure Ar 3d¹⁰ 4s¹
Valences shown 1, 2
Atomic weight( amu ) 63.546
Thermal neutron absorption cross-section( Barns ) 3.8
Photo-electric work function( eV ) 4.5
Natural isotope distribution( Mass No./% ) 65/ 30.8
Natural isotope distribution( Mass No./% ) 63/ 69.2
Atomic radius - Goldschmidt( nm ) 0.128
Ionisation potential( No./eV ) 4/ 55.2
Ionisation potential( No./eV ) 6/ 103
Ionisation potential( No./eV ) 1/ 7.73
Ionisation potential( No./eV ) 5/ 79.9
Ionisation potential( No./eV ) 3/ 36.8
Ionisation potential( No./eV ) 2/ 20.29
Mechanical Properties
Element Value
Material condition Soft
Material condition Hard
Poisson's ratio 0.343
Poisson's ratio 0.343
Bulk modulus( GPa ) 137.8
Bulk modulus( GPa ) 137.8
Tensile modulus( GPa ) 129.8
Tensile modulus( GPa ) 129.8
Izod toughness( J m⁻¹ ) 68
Izod toughness( J m⁻¹ ) 58
Hardness - Vickers( kgf mm⁻² ) 87
Hardness - Vickers( kgf mm⁻² ) 49
Tensile strength( MPa ) 314
Tensile strength( MPa ) 224
Yield strength( MPa ) 270
Yield strength( MPa ) 54
Electrical Properties
Element Value
Electrical resistivity( µOhmcm ) 1.69@20°C
Temperature coefficient( K⁻¹ ) 0.0043@0-100°C
Thermal emf against Pt (cold 0C - hot 100C)( mV ) 0.76
Physical Properties
Element Value
Boiling point( C ) 2567
Density( gcm⁻³ ) 8.96@20°C
Thermal Properties
Element Value
Melting point( C ) 1083
Latent heat of evaporation( J g⁻¹ ) 4796
Latent heat of fusion( J g⁻¹ ) 205
Specific heat( J K⁻¹ kg⁻¹ ) 385@25°C
Thermal conductivity( W m⁻¹ K⁻¹ ) 401@0-100°C
Coefficient of thermal expansion( x10⁻⁶ K⁻¹ ) 17@0-100°C
each

Choose Your Options

Close

Available Configurations

Properties common to all products in this list

Composition: Cu Form: Insulated Wire Material: Copper CAS Number: 7440-50-8 Commodity: Metals Insulation: Polyimide

We are collecting your products, please wait!...

Shipping restrictions and charges may apply for some hazardous materials.

Tolerances

Insulated Wire
Conductor Diameter ±10%
Insulation Thickness Nominal
Length +5% / -1%