Images are for guidance only and might not represent the final product.

Polyester-Insulated T1 Thermocouple Wire (Ni90-Cr10)

Available Configurations

Properties common to all products in this list

Composition: Ni 90/Cr 10 Form: Insulated Wire Material: Nickel/Chromium (Chromel) UNS Number: N06010 Commodity: Alloys Insulation: Polyester Thermocouple Compatibility: Type K / Type E (+)
Conductor Diameter Length Insulation Thickness
0.025 – 0.25 mm 0.1 – 500 m 0.002 – 0.018 mm

Need custom configurations? Please contact us.

Polyester T1 Thermocouple Insulated Wire (Ni90/Cr10) is the Chromel positive thermoelectric leg for Type K and Type E thermocouples, supplied with a polyester film insulation that provides reliable electrical isolation, a compact outer profile suited to tight-wound and multi-strand assemblies, and good dielectric properties at near-ambient temperatures. Polyester insulation is selected where a thin, lightweight coating and low moisture absorption are priorities; its service temperature ceiling is lower than polyimide, making it appropriate for thermocouple lead runs and sensing elements in moderate-temperature service rather than at the Chromel alloy's upper operating limit. Type K is the most widely deployed industrial thermocouple type, and this wire forms the positive leg of any Type K or Type E assembly. In industry, it is used for thermocouple element winding, multi-point profiling leads, and embedded temperature sensors in furnaces, kilns, and process equipment. In research, it is used for Type K and E calibration, EMF drift characterization, and thermal cycling studies where a compact, insulated Chromel conductor is required.

Health hazard/Hazardous to the ozone layer

Serious health hazard

Starting at $302.00 each
No Minimum order Free technical support Free delivery from $750

Certified Thermocouple Pairs

For applications where the pairing itself needs to be verified, not just each leg individually, certified thermocouple pairs are available through our premium manufacturing network with decades of dedicated production experience and in-house, accredited calibration laboratory.

Thermocouple wire drawing process
Capability Details
Thermocouple types available S, R, B only (platinum and platinum-rhodium alloys)
Pair matching Precision-matched from the same calibrated production batch
Manufacturing standards Platinum refined in-house to 99.995% purity; Rhodium to 99.98%. Wire diameters from 0.04mm to 1.6mm. Every batch pre-annealed and calibrated before shipping.
Testing & calibration Fixed-point method (zinc, aluminium, gold, palladium reference points). EMF evaluated against EN 60584-1 and ASTM E230/E230M tolerance classes. ISO/IEC 17025-accredited laboratory.
Certification Supplied with calibration certificate. ISO 9001 & ISO 14001 certified manufacturing.
Typical use Calibration, high-accuracy, or traceability-critical applications
To discuss a custom certified thermocouple pair, please submit a quote request or contact us.

Want to learn more? Explore our complete thermocouple range, covering both our standard and custom offerings.

Key Features

Polyester-Insulated T1 Thermocouple Wire (Ni90/Cr10) is the Chromel positive thermoelectric leg for Type K and Type E thermocouples, supplied with a polyester film insulation that provides electrical isolation, a compact outer profile, and good dielectric properties suited to near-ambient and moderate-temperature service:

Positive leg for Type K and Type E thermocouples

Chromel (Ni90/Cr10) is the positive thermoelectric leg for Type K and Type E thermocouples. Type K is the most widely deployed industrial thermocouple type.

Compact polyester insulation for tight-wound assemblies

The polyester film insulation provides reliable electrical isolation and a compact outer profile well suited to tight-wound and multi-strand thermocouple assemblies where overall wire diameter must be minimized. Low moisture absorption is a practical advantage in humid or variable-humidity installations.

Good dielectric properties at near-ambient temperatures

Polyester insulation maintains good dielectric integrity at moderate service temperatures and is selected where a thin, lightweight coating is the priority. Its service temperature ceiling is lower than polyimide, making it appropriate for thermocouple lead runs and sensing elements in moderate-temperature service rather than at the Chromel alloy's upper operating limit.

Fine conductor diameter for compact probe geometries

Conductor diameter from 0.025 mm to 0.25 mm supports compact probe geometries, multi-point profiling assemblies, and embedded sensor applications where probe mass and thermal disturbance must be minimized.

Continuous supply for element winding and multi-point installations

Supplied in lengths to 500 m, this wire supports continuous element winding and multi-point temperature profiling installations without handling breaks.

Industrial Applications

Polyester-Insulated T1 Thermocouple Wire is used for Type K and Type E thermocouple element fabrication and temperature profiling in moderate-temperature industrial and research environments:

✦ Type K and Type E thermocouple element winding
Used for thermocouple element winding in Type K and Type E assemblies for process temperature measurement in furnaces, kilns, and industrial equipment operating within the service temperature range of the polyester insulation.
✦ Multi-point temperature profiling in process equipment
Applied in multi-point profiling lead assemblies where the compact outer diameter supports routing through restricted spaces and multi-strand configurations in process equipment, reactors, and heat treatment systems.
✦ Embedded temperature sensors
Used for embedded temperature sensors in moderate-temperature industrial applications where the compact profile and low moisture absorption of the polyester insulation are the selection criteria.
✦ Type K and E calibration in research
Used in research for Type K and Type E calibration studies, EMF drift characterization, and thermal cycling investigations where a compact insulated Chromel conductor is required.

Frequently Asked Questions

Answers to the questions we are asked most often about Polyester-Insulated T1 Thermocouple Wire (Ni90-Cr10), covering the insulation's temperature limit, its role as the Type K and E + leg, how it differs from bare wire, and its applications in thermocouple lead wire for moderate-temperature process profiling and multi-strand assemblies:

What is Polyester-Insulated T1 Thermocouple Wire and how does the insulation affect its use?

This product is Chromel (Ni90/Cr10) thermocouple wire with polyester insulation, supplied in continuous spooled form as the + leg of Type K and E thermocouple assemblies. The insulation provides electrical isolation between the two legs of the thermocouple and between the conductor and any conductive surface it contacts, allowing the wire to be routed through an assembly without additional sleeving. The polyester insulation has a continuous service temperature of approximately 155 °C, which sets the maximum temperature at which the lead wire itself can operate — independently of the hot junction temperature, which may be significantly higher.

What thermocouple types use Chromel (Ni90/Cr10) as the + leg?

Chromel (Ni90/Cr10) is the + leg in Type K and E thermocouple assemblies. This insulated version provides the same thermoelectric leg as the bare wire version, with the polyester outer insulation serving as an integral electrical isolation layer for the lead section of the thermocouple assembly.

What temperature limit does the polyester insulation impose?

Polyester insulation has a continuous service limit of approximately 155 °C. This makes polyester-insulated T1 wire suited to thermocouple extension leads, multi-strand thermocouple cables, and process profiling applications where the lead wire runs through areas that do not exceed this temperature — even if the thermocouple hot junction operates at much higher temperatures. For leads running through zones above 155 °C, polyimide-insulated T1 wire (rated to approximately 315 °C) or bare wire with ceramic sleeving is more appropriate.

What are the main applications for polyester-insulated T1 wire?

Polyester-insulated T1 wire is used for Type K and E thermocouple lead wire in HVAC systems, industrial process profiling, food processing equipment, and general instrumentation where the lead wire runs through ambient or moderately elevated temperature zones. It is also used in multi-strand thermocouple cable assemblies where individual insulated conductors are bundled together in a multi-point profiling harness. The polyester insulation provides basic electrical isolation and physical protection at a lower cost than polyimide or polyurethane alternatives.

Is polyester-insulated wire solderable?

No. Polyester insulation must be mechanically stripped before soldering or welding; it does not dissolve in solder. For applications where through-insulation solderability is required — for example, in compact probe assemblies or where stripping is impractical — polyurethane-insulated T1 wire is the correct choice, as polyurethane insulation dissolves in molten solder at normal soldering temperatures.

How does Chromel bare wire differ from this insulated version?

The bare Chromel spooled wire is the raw alloy without insulation, suited to thermocouple elements that will be enclosed in ceramic sleeves, mineral-insulated sheaths, or other protective structures where insulation is applied separately. This insulated version is the ready-to-use lead wire format for the same alloy, where the polyester insulation is already applied and provides the electrical isolation needed in open-lead thermocouple assemblies and extension cables. Choose bare wire for sensor element fabrication; choose insulated wire for thermocouple lead wiring.

What diameter and length options are available for Polyester-Insulated T1 Thermocouple Wire (Ni90-Cr10)?

Polyester-Insulated T1 Thermocouple Wire (Ni90-Cr10) is available in a range of diameters and lengths. Diameter tolerance is ±10% and length tolerance is +5% / −1%. For custom configurations or non-standard requirements, please contact us.

Synonyms

Polyester-Insulated Type K Positive (KP) Thermocouple Wire Polyester T1 Thermocouple Alloy Coated Wire Ni90Cr10 T1 Thermocouple Wire Polyester-Insulated Chromel Wire Polyester T1 Thermocouple Jacketed Wire

Material Properties

Mechanical Properties
Element Value
Elongation at break( % ) 44
Modulus of elasticity( GPa ) 186
Izod impact strength( J m⁻¹ ) 108
Tensile strength( MPa ) 620-780
Electrical Properties
Element Value
Electrical resistivity( µOhmcm ) 70.6
Temperature coefficient( K⁻¹ ) 0.00032
Thermal Properties
Element Value
Maximum use temperature in air( C ) 1100
Melting point( C ) 1420
Thermal conductivity( W m⁻¹ K⁻¹ ) 19@23°C
Coefficient of thermal expansion( x10⁻⁶ K⁻¹ ) 17.2@20-1000°C
Physical Properties
Element Value
Density( gcm⁻³ ) 8.5
each

Choose Your Options

Close

Available Configurations

Properties common to all products in this list

Composition: Ni 90/Cr 10 Form: Insulated Wire Material: Nickel/Chromium (Chromel) UNS Number: N06010 Commodity: Alloys Insulation: Polyester Thermocouple Compatibility: Type K / Type E (+)

We are collecting your products, please wait!...

Shipping restrictions and charges may apply for some hazardous materials.

Tolerances

Insulated Wire
Conductor Diameter ±10%
Insulation Thickness Nominal
Length +5% / -1%