Commodity: Precious Metals Material: Platinum/Rhodium Form: Wire Composition: Pt 90/Rh 10
Diameter Length Temper ⓘ Thermocouple Compatibility Other Variants
0.013 – 1 mm 0.025 – 500 m Annealed
As Drawn
Hard
Type S (+) Pt83-Rh17
Pt60-Rh40
Pt70-Rh30
Pt80-Rh20
Pt87-Rh13
Pt94-Rh6

Need custom configurations? Please contact us.

Platinum/Rhodium Alloy Spooled Wire (Pt90/Rh10) is the standard positive-leg material for Type S thermocouples — the IEC-defined Pt-10%Rh vs. Pt thermocouple pair used for high-precision temperature measurement up to 1600 °C, and one of the most widely used thermocouple types in the glass, steel, and ceramics industries. The 10% rhodium addition strengthens the wire relative to pure platinum, improving creep resistance and reducing the risk of mechanical failure in the positive limb under sustained high-temperature service. Beyond thermometry, the combination of rhodium-enhanced strength, platinum-family chemical inertness, and stable electrical properties makes this alloy well suited to precision resistance elements in high-temperature instrumentation, catalytic wire substrates for gas-phase reaction studies, and electrode wire in electrochemical and spectroscopic systems where noble metal stability under thermal and chemical stress is a design requirement. Its oxidation resistance and consistent thermoelectric output also make it a reliable material for furnace calibration work and temperature reference systems in industrial metrology.
Starting at $404.00 each
No Minimum order Free technical support Free delivery from $750

Certified Thermocouple Pairs

For applications where the pairing itself needs to be verified, not just each leg individually, certified thermocouple pairs are available through our premium manufacturing network with decades of dedicated production experience and in-house, accredited calibration laboratory.

Thermocouple wire drawing process
Capability Details
Thermocouple types available S, R, B only (platinum and platinum-rhodium alloys)
Pair matching Precision-matched from the same calibrated production batch
Manufacturing standards Platinum refined in-house to 99.995% purity; Rhodium to 99.98%. Wire diameters from 0.04mm to 1.6mm. Every batch pre-annealed and calibrated before shipping.
Testing & calibration Fixed-point method (zinc, aluminium, gold, palladium reference points). EMF evaluated against EN 60584-1 and ASTM E230/E230M tolerance classes. ISO/IEC 17025-accredited laboratory.
Certification Supplied with calibration certificate. ISO 9001 & ISO 14001 certified manufacturing.
Typical use Calibration, high-accuracy, or traceability-critical applications
To discuss a custom certified thermocouple pair, please submit a quote request or contact us.

Want to learn more? Explore our complete thermocouple range, covering both our standard and custom offerings.

Key Features

Platinum/Rhodium Alloy Spooled Wire (Pt90/Rh10) is the IEC-defined positive-leg material for Type S thermocouples, one of the most widely used thermocouple types in high-temperature industrial measurement:

Type S Thermocouple Positive Leg

This is the Pt-10%Rh alloy specified by IEC for the positive limb of Type S thermocouples, paired against a pure platinum negative leg for high-precision temperature measurement to 1,600 °C.

Improved Creep Resistance Over Pure Platinum

The 10% rhodium addition strengthens the wire relative to pure platinum, improving creep resistance and reducing the risk of mechanical failure in the positive limb under sustained high-temperature service.

Retained Chemical Inertness and Oxidation Resistance

The alloy retains platinum-family chemical inertness and oxidation resistance while the rhodium content elevates mechanical strength and high-temperature stability, supporting long-term thermocouple performance.

Consistent Thermoelectric Output for Industrial Metrology

The alloy delivers consistent, repeatable thermoelectric output across the thermocouple’s operating range, making it well suited to furnace calibration and temperature reference systems where calibration stability over extended service periods matters.

Electrical and Catalytic Properties

Good electrical conductivity, high melting point, and catalytic activity extend this wire’s utility to precision resistance elements, catalytic wire substrates, and electrode wire in electrochemical and spectroscopic systems requiring noble metal stability.

Industrial Applications

Platinum/Rhodium Alloy Spooled Wire (Pt90/Rh10) is used wherever the Type S thermocouple standard, high-temperature mechanical integrity, or Pt-Rh alloy properties determine material selection:

✦ Type S Thermocouple Fabrication
Fabrication of the Pt-10%Rh positive limb in Type S thermocouples for temperature measurement to 1,600 °C. Improved creep resistance over pure platinum reduces the risk of positive limb failure during sustained high-temperature service.
✦ Glass, Steel and Ceramics Industry Temperature Measurement
Used in thermocouples for glass manufacturing, steel production, and ceramics processing, where the Type S thermocouple’s accuracy and the alloy’s consistent thermoelectric output are production-critical requirements.
✦ Furnace Calibration and Industrial Metrology
Applied in furnace calibration work and temperature reference systems for industrial metrology, where the reliable thermoelectric output and oxidation resistance of this alloy support accurate, reproducible calibration over extended service periods.
✦ Precision Resistance Elements and Catalytic Wire Substrates
Used as precision resistance elements in high-temperature instrumentation and as catalytic wire substrates for gas-phase reaction studies, where noble metal stability under thermal and chemical stress is a design requirement.
✦ Electrode Wire in Electrochemical and Spectroscopic Research
Applied as electrode wire in research systems requiring corrosion-resistant metallic wire at elevated temperatures, where stable electrical properties and chemical inertness support reproducible measurements.

Frequently Asked Questions

Answers to the questions we are asked most often about Platinum-Rhodium Alloy Spooled Wire (Pt90/Rh10), covering its thermocouple role as the Type S + leg, temperature range, atmosphere compatibility, and when to specify it over other platinum-rhodium alloys:

What is Pt90/Rh10 alloy wire and what is its primary application?

Platinum-rhodium alloy wire (Pt90/Rh10) combines the chemical inertness and thermoelectric stability of platinum with the mechanical strength and creep resistance that rhodium addition provides at elevated temperatures. Its primary application is as the + leg of the Type S thermocouple, covering a service range of 0–1,300 °C. The rhodium content strengthens the platinum matrix and improves resistance to grain growth at high temperatures, extending service life compared with pure platinum wire in sustained high-temperature service.

What does the rhodium addition contribute to the alloy's properties?

Rhodium is added to platinum to improve mechanical strength and resistance to creep and grain growth at elevated temperatures. Without the rhodium addition, pure platinum wire would soften progressively under load at thermocouple service temperatures, causing the wire to deform and the junction geometry to change — both of which would introduce drift in the thermocouple output. The rhodium content also raises the electrical resistivity compared with pure platinum, which is an intrinsic property of the thermocouple alloy that forms part of its thermoelectric characteriztic.

What is the service range of Type S and what atmospheres is it suited to?

Type S thermocouples use Pt90/Rh10 as the + leg, covering 0–1,300 °C. Platinum-rhodium thermocouples are suited to oxidizing atmospheres and vacuum environments. Reducing atmospheres, sulphurous gases, and metallic vapours can contaminate or dissolve the platinum-rhodium wire, causing irreversible drift that cannot be corrected by annealing. Contamination is the primary mechanism of thermocouple failure in platinum-rhodium types; maintaining a clean environment around the sensing element is more important for long-term accuracy than for base-metal types.

What is the correct temper before use in thermocouple service?

Only annealed platinum-rhodium wire should be used directly in thermocouple service. Wire supplied in as drawn or other tempers must be annealed by the customer before first use, following ASTM E220 or the equivalent EN standard, to relieve drawing stresses that would otherwise produce drift in the thermoelectric output. For certified pairs ordered through Goodfellow's certified pairing service, wire is pre-annealed before dispatch and should be re-annealed by the customer before first use.

What are the non-thermocouple applications for Pt90/Rh10 wire?

Pt90/Rh10 wire is used as a resistance heating element material in high-temperature laboratory and industrial furnaces in oxidizing atmospheres, where it offers better oxidation resistance than pure platinum at the highest furnace temperatures. It is also used in high-reliability electrical connections in aerospace and analytical instruments where platinum's chemical inertness is required alongside the mechanical strength provided by the rhodium addition. In research, it is used for custom heating devices, experimental thermoelectric studies, and as a high-temperature electrode material in electrochemical and catalytic research.

How does Pt90/Rh10 compare to other platinum-rhodium alloys in the Goodfellow range?

The Goodfellow range covers four platinum-rhodium compositions: Pt90/Rh10 (Type S positive), Pt87/Rh13 (Type R positive), Pt70/Rh30 (Type B positive), and Pt94/Rh6 (Type B negative). Higher rhodium content increases mechanical strength and creep resistance but reduces ductility and raises cost. Pt90/Rh10 is the correct grade for Type S thermocouple applications (Type S thermocouple positive leg, paired with platinum as the negative leg). Advantages of this grade: high accuracy, EN 60584-1 Class 1, long track record as a reference standard. Limitations: output drifts gradually with prolonged high-temperature exposure (recoverable by annealing).

Can Goodfellow supply certified Type S thermocouple pairs using Pt90/Rh10 wire?

Yes. Certified, precision-matched Type S pairs are available to order through Goodfellow's certified pairing service, which uses platinum-rhodium and platinum wires refined and drawn by a specializt producer operating an ISO/IEC 17025-accredited calibration laboratory. Certified pairs are supplied with a calibration certificate including EMF values at fixed reference points. Standard pairs can also be assembled by ordering the positive and negative legs separately to the same temper and diameter. Request a quote with your diameter and quantity.

What diameter and length options are available for Pt90/Rh10 wire?

Platinum-rhodium alloy (Pt90/Rh10) spooled wire is available in a range of diameters and lengths; the available diameter range for thermocouple-grade wire runs from 0.04 mm to 1.6 mm for certified-pair wire. Diameter tolerance is ±10% and length tolerance is +5% / −1%. For custom diameters or non-standard configurations, please contact us.

Synonyms

Type S Thermocouple Spooled Wire Pt-10%Rh Spooled Wire Pt-Rh Reeled Wire Pt90Rh10 Spooled Wire Platinum-Rhodium Reeled Wire

Material Properties

Mechanical Properties
Element Value
Hardness - Brinell 90-165
Elongation at break( % ) 35
Tensile strength( MPa ) 320-620
Electrical Properties
Element Value
Electrical resistivity( µOhmcm ) 18.4-19.2
Temperature coefficient( K⁻¹ ) 0.0017
Thermal Properties
Element Value
Melting point( C ) 1830-1855
Thermal conductivity( W m⁻¹ K⁻¹ ) 38@23°C
Physical Properties
Element Value
Density( gcm⁻³ ) 19.97
each

Choose Your Options

Close

Available Configurations

Properties common to all products in this list

Commodity: Precious Metals Material: Platinum/Rhodium Form: Wire Composition: Pt 90/Rh 10

We are collecting your products, please wait!...

Shipping restrictions and charges may apply for some hazardous materials.

Tolerances

Wire
Diameter ±10%
Length +5% / -1%