Goodfellow Thermocouple Wire Range

Our thermocouple wire range spans nine common types, from general-purpose base-metal wire (K, J, E, and T) to precision platinum and platinum-rhodium alloys (S, R, and B), plus the tungsten-rhenium types (C and D) for extreme high-temperature applications.

Between them, the range covers everything from cryogenic measurement up to service well beyond 1600°C, in oxidising, reducing, or protective atmospheres depending on the type.

Every type is available individually from stock, with certified, precision-matched pairs available to order for S, R, and B.

Platinum Thermocouple Wire | GoodfellowPlatinum Thermocouple Wire | Goodfellow
75+
Years of facilitating scientific innovation
170K
Huge range of advanced materials
111+
Countries served globally
ISO 9001
Quality assured products

75+

Years of facilitating scientific innovation
 

170K

Huge range of advanced materials

111

Countries served globally

ISO9001

Quality assured products

Standard Pairs vs. Certified Pairs

Choosing between our two thermocouple pairing options comes down to how much certainty you need in the match.

  Standard Pairs Certified Pairs
Source Goodfellow catalogue stock Manufactured to order by our certified partner
Types available S, R, B, K, T, E, J, C, D S, R, B only
How legs are matched Same temper and dimension; match them yourself using the reference table below Precision-matched from the same calibrated production batch
Certification Not certified as a pair Supplied with a calibration certificate
How to order Order the positive and negative leg separately, matching temper and dimension Submit your specification for a custom quote
Typical use General-purpose temperature sensing Calibration, high-accuracy, or traceability-critical applications
Standard Pairs
SourceGoodfellow catalogue stock
Types availableS, R, B, K, T, E, J, C, D
How legs are matchedSame temper and dimension; match them yourself using the reference table below
CertificationNot certified as a pair
How to orderOrder the positive and negative leg separately, matching temper and dimension
Typical useGeneral-purpose temperature sensing
Certified Pairs
SourceManufactured to order by our certified partner
Types availableS, R, B only
How legs are matchedPrecision-matched from the same calibrated production batch
CertificationSupplied with a calibration certificate
How to orderSubmit your specification for a custom quote
Typical useCalibration, high-accuracy, or traceability-critical applications

If your application needs documented, traceable accuracy, the certified route is worth the extra step. If you need a working pair quickly from stock, order both legs to the same temper and dimension using the reference table below.

Our Thermocouple Types at a Glance

Goodfellow offers nine standard thermocouple types, each sold as individual positive and negative legs. Types S, R, and B are also available as custom-certified pairs. Select types are additionally available with polyester or polyimide insulation for compact, pre-insulated leads.

Type Positive leg Negative leg Service range Typical use Pros Cons
S
Certified Pair Available
Platinum-10% rhodiumView product →
0-1300°C Precision reference and calibration-grade measurement High accuracy, EN 60584-1 Class 1, long track record as a reference standard More expensive than base-metal types; output drifts gradually with prolonged high-temperature exposure (recoverable by annealing)
R
Certified Pair Available
Platinum-13% rhodiumView product →
0-1300°C Precision reference and calibration-grade measurement Same accuracy class as Type S, with a slightly higher voltage output and improved stability More expensive than type S due to the higher percentage of rhodium
B
Certified Pair Available
Platinum-30% rhodiumView product →
Platinum-6% rhodiumView product →
0-1600°C The most demanding high-temperature environments, including glass and iron/steel processing Highest temperature ceiling of the platinum-based types, more stable under sustained high-temperature exposure than S/R Lower sensitivity at lower temperatures; EN 60584-1 Class 2 (a wider tolerance band than S/R)
T
Copper-nickel (Constantan®)View product →
-200°C to 400°C Cryogenic and low-to-moderate temperature measurement Stable and accurate at low temperature, good resistance to corrosion in moist conditions Limited to a comparatively low upper temperature; copper leg oxidises above range
J
Copper-nickel (Constantan®)View product →
-40°C to 750°C Legacy/general-purpose use, older equipment, vacuum or reducing atmospheres Low cost, performs well in reducing atmospheres Iron leg oxidises above 750°C, limiting upper range; unsuitable for damp, low-temperature environments
E
Nickel-chromium (Chromel)View product →
Copper-nickel (Constantan®)View product →
-200°C to 900°C Sub-zero to moderate-temperature sensing where signal strength matters Highest signal output of all nine types, non-magnetic Not suited to reducing atmospheres; narrower upper range than K
K
Nickel-chromium (Chromel)View product →
Nickel-aluminium (Alumel)View product →
-200°C to 1260°C General-purpose industrial sensing; the most widely used type across a broad range of applications Wide range, low cost, durable, good in oxidising atmospheres Short-range ordering in the positive leg causes reversible drift of a few degrees between roughly 250°C and 550°C; above roughly 800°C, oxidation causes progressive drift. Not suited to reducing or sulfurous atmospheres.
C
Tungsten-5% rheniumView product →
Tungsten-26% rheniumView product →
Up to 2000°C, protective/inert/vacuum atmosphere only Extreme high-temperature measurement in metallurgy, power generation, and aerospace, always under a protective atmosphere Very high temperature capability (2000°C) Oxidises rapidly in open air above 500°C; not usable in ordinary atmospheric conditions; wire is comparatively brittle
D
Tungsten-3% rheniumView product →
Tungsten-25% rheniumView product →
Up to 2000°C, protective/inert/vacuum atmosphere only Extreme high-temperature measurement in metallurgy, power generation, and aerospace, always under a protective atmosphere Compositionally close to Type C, with a marginally lower rhenium content in the negative leg (25% versus 26%) Oxidises rapidly in open air above 500°C; not usable in ordinary atmospheric conditions; wire is comparatively brittle, like Type C
Type SCertified Pair Available
Positive legPlatinum-10% rhodiumView product →
Negative legPlatinumView product →
Service range0-1300°C
Typical usePrecision reference and calibration-grade measurement
ProsHigh accuracy, EN 60584-1 Class 1, long track record as a reference standard
ConsMore expensive than base-metal types; output drifts gradually with prolonged high-temperature exposure (recoverable by annealing)
Type RCertified Pair Available
Positive legPlatinum-13% rhodiumView product →
Negative legPlatinumView product →
Service range0-1300°C
Typical usePrecision reference and calibration-grade measurement
ProsSame accuracy class as Type S, with a slightly higher voltage output and improved stability
ConsMore expensive than type S due to the higher percentage of rhodium
Type BCertified Pair Available
Positive legPlatinum-30% rhodiumView product →
Negative legPlatinum-6% rhodiumView product →
Service range0-1600°C
Typical useThe most demanding high-temperature environments, including glass and iron/steel processing
ProsHighest temperature ceiling of the platinum-based types, more stable under sustained high-temperature exposure than S/R
ConsLower sensitivity at lower temperatures; EN 60584-1 Class 2 (a wider tolerance band than S/R)
Type T
Positive legCopperView product →
Negative legCopper-nickel (Constantan®)View product →
Service range-200°C to 400°C
Typical useCryogenic and low-to-moderate temperature measurement
ProsStable and accurate at low temperature, good resistance to corrosion in moist conditions
ConsLimited to a comparatively low upper temperature; copper leg oxidises above range
Type J
Positive legIronView product →
Negative legCopper-nickel (Constantan®)View product →
Service range-40°C to 750°C
Typical useLegacy/general-purpose use, older equipment, vacuum or reducing atmospheres
ProsLow cost, performs well in reducing atmospheres
ConsIron leg oxidises above 750°C, limiting upper range; unsuitable for damp, low-temperature environments
Type E
Positive legNickel-chromium (Chromel)View product →
Negative legCopper-nickel (Constantan®)View product →
Service range-200°C to 900°C
Typical useSub-zero to moderate-temperature sensing where signal strength matters
ProsHighest signal output of all nine types, non-magnetic
ConsNot suited to reducing atmospheres; narrower upper range than K
Type K
Positive legNickel-chromium (Chromel)View product →
Negative legNickel-aluminium (Alumel)View product →
Service range-200°C to 1260°C
Typical useGeneral-purpose industrial sensing; the most widely used type across a broad range of applications
ProsWide range, low cost, durable, good in oxidising atmospheres
ConsShort-range ordering in the positive leg causes reversible drift of a few degrees between roughly 250°C and 550°C; above roughly 800°C, oxidation causes progressive drift. Not suited to reducing or sulfurous atmospheres.
Type C
Positive legTungsten-5% rheniumView product →
Negative legTungsten-26% rheniumView product →
Service rangeUp to 2000°C, protective/inert/vacuum atmosphere only
Typical useExtreme high-temperature measurement in metallurgy, power generation, and aerospace, always under a protective atmosphere
ProsVery high temperature capability (2000°C)
ConsOxidises rapidly in open air above 500°C; not usable in ordinary atmospheric conditions; wire is comparatively brittle
Type D
Positive legTungsten-3% rheniumView product →
Negative legTungsten-25% rheniumView product →
Service rangeUp to 2000°C, protective/inert/vacuum atmosphere only
Typical useExtreme high-temperature measurement in metallurgy, power generation, and aerospace, always under a protective atmosphere
ProsCompositionally close to Type C, with a marginally lower rhenium content in the negative leg (25% versus 26%)
ConsOxidises rapidly in open air above 500°C; not usable in ordinary atmospheric conditions; wire is comparatively brittle, like Type C
Type Insulation Positive leg Negative leg Service range Pros Cons
K Polyester film: a thin, lightweight film with low moisture absorption and good dielectric properties near ambient temperature; lower practical service-temperature ceiling than polyimide.
Nickel-chromium (Chromel), PolyesterView product →
Nickel-aluminium (Alumel), PolyesterView product →
Up to 155°C continuous / 200°C short-term Thin, lightweight, low moisture absorption; compact profile suited to tight-wound and multi-strand assemblies Lower temperature capability than polyimide; insulation limits the usable temperature range of the wire
K Polyimide film: higher thermal stability, chemical resistance, and dielectric integrity at elevated temperature than polyester or polyurethane; maintains insulating properties where other organic coatings degrade.
Nickel-chromium (Chromel), PolyimideView product →
Nickel-aluminium (Alumel), PolyimideView product →
Up to 315°C continuous / 427°C short-term Higher thermal stability and chemical resistance than polyester or polyurethane; retains insulating integrity closer to the alloy's full service range Less economical for moderate-temperature applications where polyester provides sufficient thermal performance
T Polyimide film, offering higher thermal stability, chemical resistance, and dielectric integrity at elevated temperature than polyester or polyurethane.
Copper, PolyimideView product →
Copper-nickel (Constantan®), PolyimideView product →
Up to 315°C continuous / 400°C short-term High thermal stability and chemical resistance versus polyester or polyurethane; suited to aerospace, chemical-process, and elevated-temperature laboratory use Polyimide insulation can be more difficult to strip and terminate than polyester or polyurethane alternatives
E Polyimide film, offering higher thermal stability, chemical resistance, and dielectric integrity at elevated temperature than polyester or polyurethane.
Nickel-chromium (Chromel), PolyimideView product →
Copper-nickel (Constantan®), PolyimideView product →
Up to 315°C continuous / 427°C short-term High thermal stability and chemical resistance versus polyester or polyurethane; suited to aerospace, chemical-process, and elevated-temperature laboratory use Polyimide insulation can be more difficult to strip and terminate than polyester or polyurethane alternatives
Type K, Polyester
InsulationPolyester film: thin, lightweight, low moisture absorption, good dielectric near ambient temperature; lower ceiling than polyimide.
Positive legNickel-chromium (Chromel), PolyesterView product →
Negative legNickel-aluminium (Alumel), PolyesterView product →
Service rangeUp to 155°C continuous / 200°C short-term
ProsThin, lightweight, low moisture absorption; compact profile for tight-wound and multi-strand assemblies
ConsLower temperature capability than polyimide; insulation limits the usable temperature range of the wire
Type K, Polyimide
InsulationPolyimide film: higher thermal stability, chemical resistance, and dielectric integrity at elevated temperature than polyester or polyurethane.
Positive legNickel-chromium (Chromel), PolyimideView product →
Negative legNickel-aluminium (Alumel), PolyimideView product →
Service rangeUp to 315°C continuous / 427°C short-term
ProsHigher thermal stability and chemical resistance than polyester or polyurethane; retains integrity closer to the alloy's full range
ConsLess economical for moderate-temperature applications where polyester provides sufficient thermal performance
Type T, Polyimide
InsulationPolyimide film, offering higher thermal stability, chemical resistance, and dielectric integrity than polyester or polyurethane.
Positive legCopper, PolyimideView product →
Negative legCopper-nickel (Constantan®), PolyimideView product →
Service rangeUp to 315°C continuous / 400°C short-term
ProsHigh thermal stability and chemical resistance versus polyester or polyurethane; suited to aerospace/chemical-process/elevated-temperature lab use
ConsPolyimide insulation can be more difficult to strip and terminate than polyester or polyurethane alternatives
Type E, Polyimide
InsulationPolyimide film, offering higher thermal stability, chemical resistance, and dielectric integrity than polyester or polyurethane.
Positive legNickel-chromium (Chromel), PolyimideView product →
Negative legCopper-nickel (Constantan®), PolyimideView product →
Service rangeUp to 315°C continuous / 427°C short-term
ProsHigh thermal stability and chemical resistance versus polyester or polyurethane; suited to aerospace/chemical-process/elevated-temperature lab use
ConsPolyimide insulation can be more difficult to strip and terminate than polyester or polyurethane alternatives
Thermocouple Wire Pairing | GoodfellowThermocouple Wire Pairing | Goodfellow

How to Build a Standard Pair

Every Goodfellow thermocouple wire is sold as an individual leg. To build a working pair, order the positive and negative legs of the same type, temper, and dimension.

Use the reference table above to find the positive and negative leg composition for your chosen type, then check each product page for available temper and dimension combinations before ordering both legs.

Both legs of a pair should share the same temper and the same dimension (diameter and length). Temper affects how the wire behaves, not just how it's supplied, so it's worth checking before you order.

How to Get Certified Pairs

For applications where the pairing itself needs to be verified, not just each leg individually, we partner with a premium, certified thermocouple manufacturer with decades of dedicated production experience and its own in-house, accredited calibration laboratory.

Manufacturing
  • Platinum and rhodium refined in-house, to a minimum purity of 99.995% (Pt) and 99.98% (Rh)
  • Wire produced and supplied in diameters from 0.04mm to 1.6mm
  • Every batch is pre-annealed and calibrated before dispatch; full annealing should be completed by the customer before first use (see "How to Choose the Right Thermocouple Wire")
Testing & Calibration
  • Each production batch is sampled and calibrated using the fixed-point method (zinc, aluminium, gold, and palladium reference points)
  • EMF values are evaluated against the tolerance classes defined in EN 60584-1 and ASTM E230/E230M
  • Testing is carried out in an ISO/IEC 17025-accredited calibration laboratory
Quality Management
  • ISO 9001 certified
  • ISO 14001 certified

Every certified pair order can include the following documentation.

Included as Standard
  • Tolerance class and applicable standard
  • Product name, diameter, batch number, and date
  • Calibration certificate with EMF values at fixed points (zinc, aluminium, gold, palladium), plus calculated EMF-vs-temperature values across 400-1600°C in 100°C steps
Available on Request
  • Chemical analysis of the positive and negative legs
  • Mechanical properties (tensile strength, ductility)

Let us know what your application requires when you submit your specification, and we'll confirm what's included in your quote.

How to Choose the Right Thermocouple Wire

The right thermocouple for your application depends on operating temperature, atmosphere, and how long the couple needs to stay accurate.

Thermocouple wire selection

Temperature range

Type B reaches the highest service temperatures in open air (1600°C); S and R (1300°C) offer higher sensitivity, the standard for precision reference work.

Wire diameter

Thinner wire responds faster but is less robust; thicker wire offers durability and longer service life.

Temper

Wire comes in four tempers: As Drawn, Stress Relieved, Hard, and Annealed. Only Annealed is ready to use; anneal others yourself first.

Atmosphere

Most types suit open air. Types C and D need a protective, inert, or vacuum atmosphere; they oxidise quickly otherwise.

Long-term stability

S and R can show a gradual, reversible output drop under sustained heat; installations are checked and replaced on schedule. B is more stable.

Contamination

Certain gases and residues can degrade platinum-based wire over time; keeping it clean protects accuracy and service life.

Annealing

Certified pairs ship pre-annealed but should be re-annealed before first use. Contact us for recommended annealing conditions; ASTM E220 covers the calibration procedure that follows.

Thermocouple wire selection

Temperature range

Type B reaches the highest service temperatures in open air (1600°C); S and R (1300°C) offer higher sensitivity, the standard for precision reference work.

Wire diameter

Thinner wire responds faster but is less robust; thicker wire offers durability and longer service life.

Temper

Wire comes in four tempers: As Drawn, Stress Relieved, Hard, and Annealed. Only Annealed is ready to use; anneal others yourself first.

Atmosphere

Most types suit open air. Type C needs a protective, inert, or vacuum atmosphere; it oxidises quickly otherwise.

Long-term stability

S and R can show a gradual, reversible output drop under sustained heat; installations are checked and replaced on schedule. B is more stable.

Contamination

Certain gases and residues can degrade platinum-based wire over time; keeping it clean protects accuracy and service life.

Annealing

Certified pairs ship pre-annealed but should be re-annealed before first use, following standard thermocouple preparation practice (see ASTM E220 for the calibration procedure this prepares the wire for).

Suisse Technology Partners | GoodfellowSuisse Technology Partners | Goodfellow
Suisse Technology Partners | Materials Analysis | GoodfellowSuisse Technology Partners | Materials Analysis | Goodfellow

Standard Pair Verification

If you need independent verification of Goodfellow's catalogue wires, on receipt, before a critical installation, or when investigating a failure, that's available through Suisse Technology Partners, a Goodfellow Group company operating an ISO/IEC 17025-accredited testing laboratory.

Composition verification
Confirm the actual alloy composition of your wire (Spark OES, ICP-OES, ICP-MS, XRF analysis), useful where purity or exact alloy ratio matters to your application, or where a supplied certificate needs independent confirmation.

Temper and mechanical properties
Verify tensile strength and hardness against the stated temper (As Drawn, Stress Relieved, Hard, or Annealed), relevant if a wire's mechanical behaviour doesn't match what was ordered.

Metallography and failure analysis
Microstructural examination to investigate contamination, grain growth, or other suspected causes of premature failure or drift, supporting root-cause diagnosis rather than guesswork.

Suisse TP's testing sits alongside, not in place of, our certified-pair service: it verifies what a standard wire or pair actually is, rather than certifying a pair as matched at the point of manufacture.

Thermocouple Wire, Ready From Stock

A sample of our standard range of insulated and bare thermocouple wires. Every type is available individually, with no minimum order.

Frequently Asked Questions

Can I order a single leg of thermocouple wire?

Yes. There is no minimum order quantity on any Goodfellow thermocouple wire. Every type, S, R, B, K, T, E, J, C, and D, is available as a single leg at standard catalogue pricing, whether you need one length for a prototype or volume for production.

What's the difference between a Standard Pair and a Certified Pair?

A Standard Pair is built by ordering the positive and negative leg of the same type, temper, and dimension separately from our catalogue stock. It isn't certified as a matched pair. A Certified Pair is manufactured to order by our certified partner: the two legs are precision-matched from the same calibrated production batch, and the pair is supplied with a calibration certificate. Certified Pairs are available for types S, R, and B only.

How do I build a Standard Pair myself?

Order the positive and negative legs of the same type, temper, and dimension. Use the types table on this page to find the correct leg composition for your chosen type, then check each product page for available temper and dimension combinations before ordering both legs. Both legs should match on temper and dimension, this affects how the wire behaves, not just how it's supplied.

Which thermocouple types does Goodfellow supply, and what temperature range does each cover?

We supply nine common types:

  • S (Platinum-10% rhodium / Platinum): 0-1300°C
  • R (Platinum-13% rhodium / Platinum): 0-1300°C
  • B (Platinum-30% rhodium / Platinum-6% rhodium): 0-1600°C
  • T (Copper / Copper-nickel): -200°C to 400°C
  • J (Iron / Copper-nickel): -40°C to 750°C
  • E (Nickel-chromium / Copper-nickel): -200°C to 900°C
  • K (Nickel-chromium / Nickel-aluminium): -200°C to 1260°C
  • C (Tungsten-5% rhenium / Tungsten-26% rhenium): up to 2000°C, protective/inert/vacuum atmosphere only
  • D (Tungsten-3% rhenium / Tungsten-25% rhenium): up to 2000°C, protective/inert/vacuum atmosphere only

See our full types table for pros, cons, and typical applications for each.

Does Goodfellow offer insulated thermocouple wire?

Yes. Selected types are available with polyester or polyimide insulation, pre-insulated for compact, ready-to-wire leads. Type K is available in both polyester and polyimide insulation; Types T and E are available in polyimide. See the Insulated Wires tab in our types table for the full range and specifications.

What's the difference between polyester and polyimide insulation?

Polyester is a thinner, lighter coating with good dielectric properties near ambient temperature, rated to roughly 155°C continuous (200°C short-term). Polyimide offers higher thermal stability and chemical resistance, rated to roughly 315°C continuous (427°C short-term), but is harder to strip for termination due to its heat and solvent resistance. Choose polyester for a compact, moderate-temperature lead; choose polyimide where higher service temperature or chemical resistance matters more than ease of stripping.

Does insulated wire reach the same temperature as the bare wire?

No. The insulation's service temperature is lower than the bare metal's rated range. Type K bare wire is rated to 1260°C, but its polyester insulation is only rated to roughly 200°C and its polyimide insulation to roughly 427°C short-term. Above the insulation's limit, the insulation fails before the metal conductor does, so it is the insulation, not the alloy, that sets the practical ceiling for insulated wire.

Is polyurethane-insulated thermocouple wire available?

A polyurethane-insulated Chromel positive leg and a polyurethane-insulated Constantan negative leg are both individually stocked, and together they form a complete Type E pairing, built the same way as our other Standard Pairs. It isn't currently listed as its own row in our Insulated Wires comparison table; contact us if you'd like this combination.

What temper should I order for accurate sensing?

Catalogue wire is stocked in four tempers: As Drawn, Stress Relieved, Hard, and Annealed. As Drawn and Hard have had no heat treatment. Stress Relieved has had partial heat treatment to remove residual stress, without a full anneal. Only Annealed wire is ready for accurate sensing straight away. If you're ordering for sensing rather than mechanical use, check the temper on the product page, and if it isn't Annealed, re-anneal before first use. Contact us for recommended annealing conditions; ASTM E220 covers the calibration procedure that follows.

Can Type C or D be used in open air?

No. Types C and D (tungsten-rhenium) are built for temperatures beyond the platinum-based types' range, but only under a protective, inert, or vacuum atmosphere. Both oxidise rapidly in open air above 500°C and are not usable in ordinary atmospheric conditions. They are not a drop-in substitute for S, R, or B.

What documentation comes with a Certified Pair?

Included as standard:

  • Tolerance class and applicable standard
  • Product name, diameter, batch number, and date
  • Calibration certificate with EMF values at fixed points (zinc, aluminium, gold, palladium), plus calculated EMF-versus-temperature values across 400-1600°C in 100°C steps (the full range applies to Type B; S and R certificates cover up to their 1300°C rated range)

Available on request:

  • Chemical analysis of the positive and negative legs
  • Mechanical properties (tensile strength, ductility)
Do I need to specify a temper for a Certified Pair?

No. Temper is fixed for all Certified Pairs. They are supplied pre-annealed as standard, so this isn't a field you need to specify when requesting a quote. Full re-annealing should still be completed by the customer before first use. Contact us for recommended annealing conditions; ASTM E220 covers the calibration procedure that follows.

What certifications back a Certified Pair?

Our certified partner refines platinum and rhodium in-house to a minimum purity of 99.995% (Pt) and 99.98% (Rh), and produces wire in diameters from 0.04mm to 1.6mm. Each production batch is calibrated using the fixed-point method against the tolerance classes defined in EN 60584-1 and ASTM E230/E230M, in an ISO/IEC 17025-accredited calibration laboratory. The manufacturing partner holds ISO 9001 and ISO 14001 certification.

Can I get a wire I already own independently tested?

Yes, through Suisse Technology Partners, a Goodfellow Group company operating an ISO/IEC 17025-accredited testing laboratory. Available services include composition verification (Spark OES, ICP-OES, ICP-MS, XRF analysis), temper and mechanical property verification (tensile strength and hardness), and metallography for failure analysis. This verifies what a standard wire or pair actually is, it doesn't certify a pair as matched at the point of manufacture, that's what the Certified Pair service is for.

How do I request a Certified Pair, and what will I need to provide?

Certified Pairs are made to order, so pricing, lead time, and any minimum order requirement are confirmed at quote stage based on your specification. You'll need to specify the thermocouple type (S, R, or B), diameter and length, and any additional documentation required. Submit your specification through our Certified Pair request form and our team will follow up with a quote.

Need Expert Advice?

Why Goodfellow?

  • No minimum order
  • Over 170,000 advanced materials and 5,000 reference materials
  • Supply Chain Management:
    sourcing custom materials for your needs
  • Materials customization:
    Custom parts for prototyping | Full product modification | Micro-machining | Microfabrication | Rolling
  • Fast global delivery:
    Worldwide shipping and customs clearance, to your door. All stock items are dispatched within 48-72 hours
  • Commercial arrangements:
    Call off orders | Buffer stock | Fixed and contract pricing* | Discounts for increased volumes
  • We help you innovate into the future.
*Conditions apply

What's New

Copper foil, aluminium foil, nickel foam and platinum wire used in battery, hydrogen and fusion research
How Advanced Materials Tackle Climate Change
As COP31 meets in Antalya, we look at the metals, polymers and alloys powering solar, batteries, electronics, hydrogen and fusion, and...
Read more
11 November 2026
Robotic arm painting a car in a factory
Materials for the Future of Engineering - Goodfellow at AES 2026
Discover specialist materials for tomorrow’s engineering challenges, from aerospace and defence to clean energy, with Goodfellow at...
Read more
28 October 2026
Huntingdon MP visit
Goodfellow drives home the importance of advanced manufacturing during MP visit
Goodfellow welcomes UK Shadow Minister Ben Obese-Jecty to its UK facility to discuss advanced manufacturing, international trade and...
Read more
6 October 2026

About Goodfellow

For over 75 years, we've been your trusted partner in scientific advancement, supporting researchers and businesses globally with high-quality advanced materials.

Our comprehensive catalog features over 170,000 speciality materials, forms and components, which are available from small research quantities to larger production requirements. We offer you fast dispatch and complimentary global delivery, ensuring an exceptional customer experience.