Images are for guidance only and might not represent the final product.

Platinum Classic Crucible with Lid

Available Configurations

Properties common to all products in this list

Composition: Pt Form: Crucible Material: Platinum CAS Number: 7440-06-4 Commodity: Precious Metals Purity: 99.99% (4N)
Outside Diameter Inside Diameter Height
26 – 68 mm 15.5 – 41 mm 24 – 74 mm

Need custom configurations? Please contact us.

Platinum Classic Crucible with Lid (99.99% purity) pairs the standard tapered platinum crucible with a matching platinum lid, providing sample containment during heating for applications where volatile loss, dust, or sample scatter during thermal treatment would compromise the result. Available across the full classic range from OD 26 mm to OD 68 mm, it is the standard configuration for Loss on Ignition testing, volatile matter determination, and residue on ignition analysis under European Pharmacopoeia and USP gravimetric methods, where the lid controls airflow and prevents external contamination of the sample during the ignition cycle. The lid is not permanently sealed, allowing gas exchange as required, but significantly reduces sample loss during heating and cooling. Both crucible and lid are manufactured from 99.99% pure platinum to ensure that the containment system as a whole contributes no contamination to the measurement. Goodfellow supplies crucible and lid as a matched set with full material certification and traceability documentation for regulated laboratory environments.
Starting at £940.00 each

Key Features

Platinum Classic Crucible with Lid is a matched set of tapered crucible and lid in 99.99% pure platinum, supplied for contained heating where sample integrity is critical.

High Purity Platinum

Both the crucible and the lid are manufactured from platinum of 99.99% purity. Because every part of the containment system uses the same high purity grade, neither component introduces foreign elements into the sample. The vessel as a whole contributes no contamination to the measurement, so recorded mass changes reflect the behavior of the sample alone.

Matched Lid

The crucible is paired with a platinum lid made to fit its rim, and the two are supplied together as a matched set. The fitted lid encloses the sample during heating, limiting scatter of material and shielding the contents from dust and other external contaminants. This containment is maintained through both the heating and cooling stages.

Unsealed Lid Design

The lid rests on the crucible rather than being permanently sealed, so gas exchange between the sample and the surrounding atmosphere can still take place as required. At the same time, the lid restricts airflow over the sample surface. This balance significantly reduces loss of volatile material and fine particles without fully isolating the contents from the furnace atmosphere.

Tapered Classic Profile

The crucible follows the standard tapered classic form, with walls that narrow toward the base. The same profile is used across the full classic size range, and each crucible is paired with a correspondingly sized lid. This consistent geometry allows the crucible and lid to be selected at the required capacity while keeping the same form and containment behavior.

Certification and Traceability

The crucible and lid are supplied as a matched set with full material certification. Each set comes with traceability documentation covering the platinum used in both components. This documentation confirms the purity of the containment system and supports record keeping where material provenance must be formally demonstrated and retained.

Industrial Applications

Analytical laboratories, including those working in regulated environments, select this platinum crucible and lid set for gravimetric ignition methods that require contained heating.

✦ Loss on Ignition Testing
Loss on Ignition testing is the standard application for this crucible and lid configuration. The sample is weighed, ignited, and reweighed to quantify the mass lost during heating. With the lid in place throughout the ignition cycle, laboratories can attribute the measured loss to the sample itself rather than to material carried out of the vessel.
✦ Volatile Matter Determination
Volatile matter determination separates the fraction of a sample driven off by heating from the residue that remains. Covered crucibles are used in this work so that the result reflects controlled release under the test conditions. The set allows laboratories to run repeatable determinations and compare results between material batches and between analysts.
✦ Residue on Ignition Analysis
Residue on ignition analysis determines the material remaining after a sample has been fully ignited. The result is typically a small residual mass, so even minor gains or losses during handling affect the reported value. The covered set allows the ignition, cooling, and final weighing steps to be carried out in a single vessel, which keeps the procedure straightforward.
✦ Pharmacopoeial Gravimetric Methods
Pharmaceutical laboratories following pharmacopoeial gravimetric methods use this covered configuration as the standard vessel for ignition-based tests. Specifying the crucible with its lid supports alignment with method requirements and helps results withstand review. It also allows a single, consistent vessel type to be used across multiple compendial procedures within the same laboratory.
✦ Regulated Laboratory Environments
Laboratories operating under regulatory oversight need to demonstrate that the equipment used in testing is suitable and documented. Because the set arrives with its documentation package, it can be entered directly into equipment records and quality systems. This supports audit readiness and simplifies qualification of the vessel before it enters routine analytical service.

Synonyms

Pt Classic Crucible with Lid Platinum Crucible with Cover Lidded Platinum Crucible Platinum Laboratory Crucible with Lid Pt Crucible with Lid

Material Properties

Atomic Properties
Element Value
Atomic number 78
Crystal structure Face centred cubic
Electronic structure Xe 4f¹⁴ 5d⁹ 6s¹
Valences shown 1,2,3,4
Atomic weight( amu ) 195.08
Thermal neutron absorption cross-section( Barns ) 9
Photo-electric work function( eV ) 5.3
Natural isotope distribution( Mass No./% ) 192/ 0.79
Natural isotope distribution( Mass No./% ) 196/ 25.30
Natural isotope distribution( Mass No./% ) 190/ 0.01
Natural isotope distribution( Mass No./% ) 195/ 33.80
Natural isotope distribution( Mass No./% ) 198/ 7.20
Natural isotope distribution( Mass No./% ) 194/ 32.90
Atomic radius - Goldschmidt( nm ) 0.138
Ionisation potential( No./eV ) 1/ 9.0
Ionisation potential( No./eV ) 2/ 18.6
Mechanical Properties
Element Value
Material condition Hard
Material condition Soft
Poisson's ratio 0.39
Poisson's ratio 0.39
Bulk modulus( GPa ) 276
Bulk modulus( GPa ) 276
Tensile modulus( GPa ) 170
Tensile modulus( GPa ) 170
Hardness - Vickers( kgf mm⁻² ) 40
Hardness - Vickers( kgf mm⁻² ) 100
Tensile strength( MPa ) 200-300
Tensile strength( MPa ) 125-150
Yield strength( MPa ) 14-35
Yield strength( MPa ) 185
Electrical Properties
Element Value
Electrical resistivity( µOhmcm ) 10.58@20°C
Temperature coefficient( K⁻¹ ) 0.00392@0-100°C
Physical Properties
Element Value
Boiling point( C ) 3827
Density( gcm⁻³ ) 21.45@20°C
Thermal Properties
Element Value
Melting point( C ) 1772
Latent heat of evaporation( J g⁻¹ ) 2405
Latent heat of fusion( J g⁻¹ ) 101
Specific heat( J K⁻¹ kg⁻¹ ) 133@025°C
Thermal conductivity( W m⁻¹ K⁻¹ ) 71.6@0-100°C
Coefficient of thermal expansion( x10⁻⁶ K⁻¹ ) 9@0-100
each

Choose Your Options

Close

Available Configurations

Properties common to all products in this list

Composition: Pt Form: Crucible Material: Platinum CAS Number: 7440-06-4 Commodity: Precious Metals Purity: 99.99% (4N)

We are collecting your products, please wait!...

Shipping restrictions and charges may apply for some hazardous materials.